Yueqing Langir Electric Co., Ltd.
Main products:vandalproof switch,floor heating thermostat,indicator lamp,illuminated pushbutton switch,rotary switch
Products
Contact Us
  • Contact Person : Ms. Ni Rena
  • Company Name : Yueqing Langir Electric Co., Ltd.
  • Tel : 86-577-62737672
  • Fax : 86-577-62737671
  • Address : Zhejiang,Wenzhou,Xuezhai Industrial Zone, Liushi, Yueqing
  • Country/Region : China
  • Zip : 325604

50W triple output swithcing power supply T-50 for good quality

50W triple output swithcing power supply T-50 for good quality
Product Detailed
50W triple output swithcing power supply T-50 for good quality 1.LED indicator for power on. 2.Cooling by free air convection

50W triple output swithcing power supply T-50 for good quality

1. Universal AC input/ full range

2. Protections: short circuit/ overload/ over voltage

3. Cooling by free air power on

4. 100% full load burn-in test

5. LED indicator for power on

6. All using 105°c long life elctrolytic capacitors

7. Withstand 300VAC surge input for 5 second

8. High operating  temperature up to 70°c

9. Withstand 5G vibrtion test

10. High efficiency, long life and high reliablity

11. 3 years warranty 

Model SpecificationT-50AT-50BT-50CT-50D
CH1CH2CH3CH1CH2CH3CH1CH2CH3CH1CH2CH3
DC output voltage5V12V-5V5V12V-12V5V15V-15V5V15V24V
Output voltage error (Note2)±2%±5%±5%±2%±5%±5%±2%±5%±5%±2%±6%±6%
Rated output current7A1A1A5A1A1A4A1A1A3A1A1A
Output current rage0.6-7A0.2-1A0.2-1A0.6-5A0.2-1A0.2-1A0.6-4A0.2-1A0.2-1A0.6-4A0.2-2A0.2-1A
Wave and noise(Note3)100mV100mV100mV100mV100mV100mV100mV100mV100mV50mV120mV120mV
Inlet stability(Note4)±0.5%±0.5%±0.5±0.5%±0.5%±0.5±0.5%±0.5%±0.5±0.5%±1%±1%
Load stability(Note5)±1%±4%±4%±1%±4%±4%±1%±4%±4%±1%±5±5%
DC output power52W49W50W51W
Efficiency66%69%71%72%
Adjustable range for DC voltageCH1+10,-5%CH1+10,-5%CH1+10,-5%CH1+10,-5%
AC input voltage range85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC
Input current1.6A/115V 0.8A/230V
AC impulse currentCold-start current 20A/115V 40A/230V
Leakage current<0.5A/240VAC
Overload protection

105%~150% Type:PULSING HICCUP SHUTDOWN Reset auto recovery

Over-voltage protection……
High-temperature protection 
Temperature coefficient±0.03%°C(0~50°C) ON+5V OUTPUT
Setup rise hold up time200ms,50ms,16ms
Vibration10~500Hz,2G 3AXES 10min./1cycle,Period for 60min,Each axes
Withstand voltage

Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistanceInput and output interval,Input and enclosure,Output and enclosure:500VAC/100M Ohms
Working temperature and humidity-10°C~+60°C,20%~90%RH
Store temperature and humidity-20°C~+85°C,10%~95%RH
Overall dimension159*97*38mm
Weight0.54Kgs
Safety standardsMeet UL1012 requirement(Not apply for the mark)
EMC standards……
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°C 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2,3,11must be knocked down.

50W triple output swithcing power supply T-50 for good quality



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.